ATTENTION!!
It is forbidden to exceed the maximum regulation values in case of using fuel
with higher l.h.v. by 4.9 kWh/kg.
7.10 Switch-off
Interrupt feeding the screw and powering the fan by acting on the switch on the electronic
control unit's control panel to switch-off the generator (see attachment "A" or “B”).
Generator can also be switched off through no fuel in the hopper.
7.9 Mobile grate speed regulation
The mobile grate is moved by gear motor that turn a threaded bar giving an alternate hor-
izontal move to the structure of the grid mobile placed in the lower part of the basement.
The speed of the alternate movement of the grate is controlled by limit switch and the
electronic control board according to the different functioning phases of the generator.
This speed is regulated at its minimum to have the fuel as much time as possible on the
grate surfaces.
limit switch minimum
stroke
limit switch max stroke
contact bar