44
© 2018 Dallmeier | www.dallmeier.com
DDF51(X)0HDV-DN-IM Commissioning
11 Pin Assignment – Interface Board Series 5100
The “Contact IN/OUT” and “RS485” terminal blocks can be easily wired
without tools by directly inserting rigid conductors or flexible conductors with
ferrules (push-in spring connection).
To disconnect the conductors from the push-in terminal blocks again, gently in
-
sert a micro precision screwdriver (type: flat-bladed, blade thickness: 0.4 mm,
blade width: 2.0 mm) or a similar tool into the rectangular opening below each
conductor and pull out the conductor. Note, however, that disconnecting the
conductors is only possible after the camera module has been removed (see
optional step
❺
Interface Board Series 5100
12 V DC
Power IN
Audio OUT
Audio IN
Contact IN/OUT
RS485
Summary of Contents for DDF51 0HDV-DN Series
Page 1: ...006830 1 0 2 2018 12 19 IM DDF51 X 0HDV DN Commissioning English ...
Page 21: ......
Page 57: ......
Page 58: ......
Page 59: ......