6 www.dallmeier.com
Connections DIS-2/M UTP
Technical Data
Power supply
12 V AC ± 5 %
Power consumption
Max. 25 W
Thermal output
Max. 85 BTU/h
Temperature
+5°C up to +40°C (41°F – 104°F)
Humidity
5 – 70 % RH, non-condensing
Atmospheric load
Dust-free
Weight
Approx. 2,5 kg (Variant 700 with 2
x
HDD)
Contact IN/OUT
Control inputs (Contact IN)
Relais (Contact OUT)
A
Contact IN/OUT
B
LAN (RJ 45)
C
Video IN/OUT (BNC)
D
S-Video (mini DIN 4)
E
UTP/RS 485
F
Audio IN/OUT (3,5 mm phone jack)
15
16
13
11
9
7
5
3
1
14
12
10
8
6
4
2
PIN
Function
2/4
w/o
6
Contact 1
8
Contact 2
10
Contact 3
12
Contact 4
14/16
GND
PIN
Function
1/3
Relay 1
5/7
Relay 2
9/11
Relay 3
13/15
Relay 4
Relay (Contact OUT)
The output relays are floating and galvanically separated.
Value
Condition
Max.
Switch capacity
max. 12 W
Switch voltage
DC or peak AC
max. 12 V
Switch current
DC or peak AC
max. 1 A
A
B
C
D
E
F
UTP/RS485 female connector
PIN
Function
PIN
Function
1
UTP Video (+)
5
UTP Audio (–)
2
UTP Video (–)
6
RS 485 (B)
3
RS 485 (A)
7
inactive
4
UTP Audio (+)
8
inactive
12 3 4 5 6 7 8
1