background image

7

Dallmeier electronic

PView  Station  PVS  IV

Observe the rated voltage

The unit can be damaged or destroyed by the application of an incorrect voltage.
The mains voltage must always match the rated voltage of the unit. The rated voltage is 

specified on the rating plate of the unit.

Observe ratings

Unsuitable ambient conditions and improper installation (mainly too high ambient tempera-

ture and insufficient ventilation) may reduce the unit’s life cycle. Ensure compliance with the 

stated operating conditions (see technical data), requirements at the installation site and, if 

applicable, maintenance regulations.

Expansion components/peripheral devices

Use only expansion components conforming with the technical data of the unit. Inappropriate 

peripheral devices may result in the violation of local laws and regulations and damages 

to the unit. Furthermore, the use of peripheral devices that are not certified by Dallmeier 

electronic results in loss of warranty. In case of doubt, contact the sales partner responsible 

for your area.

Do not move while in operation

Strong vibrations can cause damage to the unit, in particular to the hard disk(s). Therefore, 

do not bump the unit or move it in a jerky motion while in operation. Instruct the cleaning 

personnel accordingly if necessary!

Do not open the unit

Do not open the housing of the unit. There are no components inside the unit that require 

maintenance by the user. The inspection, maintenance and repair with an open housing 

must only be carried out by trained and authorized professionals (installer).

Penetration of foreign bodies and liquids

No objects or liquids may be allowed to get into the device. In this case, immediately dis-

connect the unit from the power supply (pull out the power plug). Please contact the sales 

partner responsible for your area.

Measures to be taken in the event of damage and burnt smell

If you notice burnt smell or formation of smoke from a unit, immediately disconnect it from 

the power supply (pull out the power plug). Please contact the sales partner responsible 

for your area.

Disposal

Disconnect the unit from the power supply. Remove all connected units and system com-

ponents. Return the unit to your respective sales partner.

Summary of Contents for PVS IV

Page 1: ...1 Dallmeier electronic PView Station PVS IV Rev 1 0 0 080528 English Workstation PVS IV Installation and Configuration...

Page 2: ...er accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation e g print or spelling errors and for those not caused by intention or g...

Page 3: ...Certifications 9 4 Installation and mounting 10 4 1 Requirements at the installation site 10 4 3 Installation in a 19 standard rack 11 5 Views and connection assignment 12 5 1 Front view 12 5 2 Connec...

Page 4: ...configuration of the device General notes on the product and technical data are additionally provided The target audience is exclusively specially trained and authorized professionals instal lers 1 3...

Page 5: ...rect configurations or incorrect actions NOTE ANOTE offers information on principles special features and efficient procedure as well as general recommendations Expression Expressions in bold and ital...

Page 6: ...ded instructions notes and warnings Regulations surveillance systems The use of video and audio surveillance systems is strictly regulated in most countries Therefore inform yourself on laws and regul...

Page 7: ...responsible for your area Do not move while in operation Strong vibrations can cause damage to the unit in particular to the hard disk s Therefore do not bump the unit or move it in a jerky motion wh...

Page 8: ...ntation PVS IV Installation und Konfiguration CD inclusive software documentations The scope of delivery may differ depending on the ordered equipment or device variant The device s range of functions...

Page 9: ...es The PView Station PVS IV is especially characterised by the following functions and pro perties l Operating system Windows XP l DVD R RW writer l 1000 Mbit LAN interface l HDD capacity min 160 GB l...

Page 10: ...direct sunlight l with unsuitable ambient temperatures see technical data l near sources of strong radiation i e X rays radio transmitters or magnetic fields l with corrosive surroundings e g gases o...

Page 11: ...he bracket 2 Pay attention to the case feet that must fit into the notches A 3 Screw together bracket and case from the underside with 3 screws see fig 4 2 1 to 3 4 Mount the PVS IV into the 19 standa...

Page 12: ...PView Station PVS IV 5 Views and connection assignment 5 1 Front view 1 Panel Filter pad 2 Power LED Lights whenever the device is switched on 3 Status LEDs inactive 4 USB 2 0 interface 5 Panel DVD d...

Page 13: ...e This output will be activated as M1 in case of a PVS IV version without additional VGA card 6 2 x RJ45 inactive 7 2 x USB 2 0 8 LAN port RJ45 9 Mic IN red 10 Line OUT green 11 Line IN blue 12 M4 DVI...

Page 14: ...itor have to be connected accordingly to M3 and M4 Variant 1 standard with graphics card l M1 and M2 breakout cable are active l M3 and M4 main board are inactive Variant 2 all four monitor connection...

Page 15: ...esting to enter the serial number will be displayed when the Dallmeier software is starting if the licence dongle is not connected accurately If the dialog to enter the serial number is displayed proc...

Page 16: ...NOTE Note the documentation of the operating system and peripheral devices 7 2 Monitors Open the desktop context menu by right clicking on the desktop Select Properties Select the Settings tab in the...

Page 17: ...ut M1 1 M2 2 M3 3 M4 4 see figure 7 2 To configure other monitors proceed analog as above 7 3 Software The PView PGuard and SmartGUI software is already installed on the PVS IV It finally has to be co...

Page 18: ...er changes is dependent upon the installa tion site and the degree of soiling associated with it In normal office rooms checking every three months is generally suffici ent while a monthly check would...

Page 19: ...ard 1 x 3 5 Exchangeable hard disks optional 1 x 3 5 Internal hard disk optional 1 x 3 5 Max storage capacity 3 x 750 GB Interfaces Video OUT 1 x VGA 1 x DVI Audio Line IN 1 x Audio Line OUT 1 x MIC I...

Page 20: ...20 Dallmeier electronic PView Station PVS IV 9 2 Technichal drawing Unit mm Fig 9 1 130 with feet...

Page 21: ...any is responsible for this declaration Dallmeier electronic GmbH Co KG Cranachweg 1 D 93051 Regensburg The measurements were carried out in accredited laboratories For the evaluation of above mention...

Reviews: