Technical Data

Dimensions W x H x D

Approx. 230 x 85 x 150 mm (9.0" 

×

 3.6" 

×

 5.9") without feet 

Approx. 280 x 95 x 150 mm (11.0“ 

×

 3.7“ 

×

 5.9“) with feet

Voltage supply

12 V DC + / – 5 %

Power consumption

Max. 55 W

Heat power

Max. 188 BTU/h

Ambient temperature

+5°C to +40°C (41°F to 104°F), +20°C to +25°C (68°F to 77°F) recommended

Humidity

5 – 70 % RH, not condensing

Atmospheric load

Dust-free

Weight

Approx. 4 kg (9 lbs)

A Fuse

N

Serial Interface COM 2

×

 20 mm, type T, 3.5 A

D-SUB, 9 pins, RS232

B Power Supply 12V DC

O Video IN 

(1-8)

ODU socket, 2-pole, 12V DC 

±

 5%

D-SUB, 15-pole, 75 Ohm, 1 Vpp (for D-SUB/BNC adapter cable)

C 12V DC OUT

P

AUX / Line IN

Weidmüller socket, 2-pole, 12V DC ± 5% (3.2 A max.)

3.5 mm phone jack, 16 kOhm, 2.828 Vpp (for intercom)

D Status LED (Power)

Q Audio OUT

Blue / The recorder is in operation.

3.5 mm phone jack, 1 kOhm, 2.828 Vpp (for intercom)

E Status LED (Record)

R

Video OUT VGA

Green / The recorder is recording.

Mini-D-SUB, 15-pole, VGA, 1024 x 768 (only configuration, no video)

F Status LED (Alarm)

S

Video OUT CVBS (1-2)

Orange / The recorder is in alarm state.

2x BNC, 75 Ohm, 1 Vpp, CVBS (video analogue cameras, no configuration)

G Status LED (Error)

T

Ethernet Interface

Red / The recorder indicates an error.

RJ45, 10/100/1000 mbps

H Function Button

U

Audio IN 

(1-8)

Unmount removable hard disk (short push) / Shut down (long push)

D-SUB, 15-pole, 1 kOhm, 2.828 Vpp (for D-SUB/Cinch adapter cable)

I

Contact IN Cameras

 (1-8)

V

USB Interface

8 pins on Weidmüller 20 pins

4

×

 USB 2.0, type A

J

Contact IN Global 

(1-4)

W Flash Memory

4 pins on Weidmüller 20 pins

CF card, type 1

K Relay OUT

 (1 and 2)

X

Mouse / Keyboard

4 pins on Weidmüller 20 pins

PS/2, black (direct connection or via mouse + keyboard adapter)

L Serial Interface

Y

Not Active

2 pins on Weidmüller 20 pins, RS485 (for Dallmeier PTZ domes only)

2

×

 3.5 mm phone jack

M Serial Interface COM 1

Z

Removable Hard Disk

D-SUB, 9 pins, RS232

2,5" HDD in removable tray

Summary of Contents for VideoNetBox eXd

Page 1: ...Dallmeier VideoNetBox eXd Commissioning 003579 Rev 1 0 0 English...

Page 2: ...y 2 Safety Instructions 3 HDD Mounting 4 Mounting 5 Connections 6 Login 8 Dimensions 10 Validity This documentation applies to the audio and video server VideoNetBox eXd It has been produced on basis...

Page 3: ...tions damages and data loss and can result in loss of warranty Documentation Carefully and completely read the documents included in delivery Always observe the contained instructions notes and warnin...

Page 4: ...ested and released for mounting by Dallmeier HDD whitelist in the Partner Forum all hard disk drives may not be formatted or partitioned Mounting Insert the HDD tray into the guide rail Slide the hard...

Page 5: ...holes appropriate for the designated anchors screws Use proper anchors appropriate for the condition of the mounting site Insert the anchors into the 4 drilled holes Mount the recorder with 4 screws C...

Page 6: ...for intercom D Status LED Power Q Audio OUT Blue The recorder is in operation 3 5 mm phone jack 1 kOhm 2 828 Vpp for intercom E Status LED Record R Video OUT VGA Green The recorder is recording Mini...

Page 7: ...r 1 2 Contact IN H and I Pin Assignment Function 3 Contact 1 Camera 1 Start recording 4 Contact 2 Camera 2 Start recording 5 Contact 3 Camera 3 Start recording 6 Contact 4 Camera 4 Start recording 7 C...

Page 8: ...of the passwords and of the network parameters is necessary for remote access e g Dallmeier PView 7 Left click the background The Recorder login dialogue is displayed Commissioning Connect the recorde...

Page 9: ...in Password Serial number e g DAE 12345678 Note that the definition of the passwords and of the network parameters is necessary for remote access e g Dallmeier PView 7 Login Note the documentation Ins...

Page 10: ...Measures in millimetre mm 280 mm 11 0 150 mm 95 mm 3 6 230 mm 9 0 100 mm 3 9 256 mm 10 1 4 mm 0 2 10 www dallmeier com Dimensions...

Page 11: ...11 Notes Safety HDD Mounting Mounting Login Connections Dimensions...

Page 12: ...the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising due to mino...

Reviews: