Fig. 7-10
If the
Enable
checkbox is checked, the marked field contact data will be displayed in the
track playback. However, this is only possible for data that are sent to the module.
In default state, all types of field contact data are activated for the display. Deactivate those
that you do not require by unchecking the checkbox.
During the playback the data are displayed in the image that was recorded when the data
were received (in other words when the field contact was received). The duration of the
display depends on the value set in
Display time
.
7.7.2
Fieldcontact display position
To ensure that the display of the field contact data on the evaluation station or interface does
not cover any important image sections, you can define the position of the display.
Ø
Click on
Common settings
>
Fieldcontact display ...
>
Position
.
Fig. 7-11
A screen will be shown through the blue rectangle background on the right-hand side of the
dialogue (Dallmeier logo). The white lines represent the stylized playback panel of a typical
evaluation station.
The white rectangle (with the blue corner) symbolizes the screen area in which the field
contact data are displayed.
The display area can be repositioned using a drag & drop technique.
Precise positioning is possible using the coordinates that are displayed on the left-hand side
of the dialogue.
X Pos.
denotes the horizontal position of the display area and
Y Pos.
its
vertical position, relative to its top left-hand corner.
The position details are entered in pixel form, relative to the full resolution for PAL or
NTSC.