background image

Caution:

 Avoid placing the scale in direct sunlight, this may cause discoloration or malfunction.  

Replace all batteries at the same time. Do not replace only a portion of the 6 batteries as this may cause 
a malfunction.  

If the scale is not to be used for a long period of time, remove all batteries from the battery 
compartment to avoid leakage which may cause damage to this scale.  

Avoid overloading the scale, as this may cause permanent damage.  

Keep the scale away from water. This scale is not water resistant. Shock, injury and electrical damage 
can occur if used in a wet location!  

Matter charged with static electricity could affect accuracy. Discharge all static electricity. As example, 
one method is to use electrification prevention spray, and spray it on both side of weighing platform.  

SPECIFICATIONS

 

Model number i500 Capacity 500g Division .1g 
Model number i1200 Capacity 1200g Division .1g 
Platter / Tray 145•~145mm 
Net/gross weight 460/650g 
Package Standard carton: 22.5•~15.5•~4.8(cm3) 
24 Units in one box: 48•~48•~22(cm3) 
Operating Temperature 0-40c (32-104f) 
Power source 6•~AA Size Batteries or AC/DC 
Adapter 9V/100mA (optional)  

CALIBRATION

 

When to calibrate - calibration is RARELY required. Calibration may be required when the scale is first 
set up for use, or if the scale is moved to a different altitude or gravitation. This is necessary because the 
weight of a mass in one location is not necessarily the same in another location. Also, with time and use, 
mechanical deviations can occur.  

For the i500 you must have an accurate 500 gram weight or a combination of weights that equals 500 
grams in order to calibrate. 

For the i1200 there are 2 models:

 For the 2003 i1200 you must have an 

accurate 1200 gram weight or a combination of weights that equals 1200 grams in order to calibrate. 
For the 2004 i1200 you must have an accurate 1000 gram weight or a combination of weights that 
equals 1000 grams in order to calibrate. For the i2600 (2004-Current models) the correct calibration 
weight is 2000 grams. For i2600 (2002 & 2003 models) the correct calibration weight is 2600 grams  

Calibration Procedure:

  

1.

 

Before entering calibration mode, be sure the scale is powered OFF (must be OFF) 

Summary of Contents for I5500

Page 1: ...on You can use a paperclip to slightly bend the battery prongs to make them have a better connection Also some poorly designed batteries have recessed or partially obstructed battery terminals This may cause your prongs to be touching the plastic housing of the battery instead of the metal battery terminal A Faulty AC adaptor can cause your scale to act unstable with numbers jumping all around Ple...

Page 2: ... 24 Units in one box 48 48 22 cm3 Operating Temperature 0 40c 32 104f Power source 6 AA Size Batteries or AC DC Adapter 9V 100mA optional CALIBRATION When to calibrate calibration is RARELY required Calibration may be required when the scale is first set up for use or if the scale is moved to a different altitude or gravitation This is necessary because the weight of a mass in one location is not ...

Page 3: ...a given number of samples of an item on the pan the Sample Size should be either 10 20 50 or 100 pieces The weight of these samples will show on the display 4 Press the SET key several times to put the scale in PCS mode the indicator should be on pcs 5 Select the sample size the same as you chose above by pressing the PCS key press it as many times as necessary to put it in the correct sample size...

Page 4: ...tor Indicates when the scale zero is correct Weighing unit Stable indicator Indicates when the reading is stable Low battery indicator PREPARATION Installing batteries Connecting the AC adaptor Remove the battery compartment and insert six Dry batteries R6P LR6 AA size into the battery compartment Use extreme care that the polarities plus and minus are correct Plug the AC adapter to the AC adapter...

Page 5: ...yed and press ZERO Place the objects to be weighed in the container When the reading becomes stable the stable indicator is displayed FUNCTION SETTINGS 2003 Current models only 1 Enter function setting mode Press ON OFF to turn the power off Press Mode first then press ON OFF while keeping Mode pressed the display will show b_on arrow direct to light this means enter the selection of auto backligh...