Caution:
Avoid placing the scale in direct sunlight, this may cause discoloration or malfunction.
Replace all batteries at the same time. Do not replace only a portion of the 6 batteries as this may cause
a malfunction.
If the scale is not to be used for a long period of time, remove all batteries from the battery
compartment to avoid leakage which may cause damage to this scale.
Avoid overloading the scale, as this may cause permanent damage.
Keep the scale away from water. This scale is not water resistant. Shock, injury and electrical damage
can occur if used in a wet location!
Matter charged with static electricity could affect accuracy. Discharge all static electricity. As example,
one method is to use electrification prevention spray, and spray it on both side of weighing platform.
SPECIFICATIONS
Model number i500 Capacity 500g Division .1g
Model number i1200 Capacity 1200g Division .1g
Platter / Tray 145•~145mm
Net/gross weight 460/650g
Package Standard carton: 22.5•~15.5•~4.8(cm3)
24 Units in one box: 48•~48•~22(cm3)
Operating Temperature 0-40c (32-104f)
Power source 6•~AA Size Batteries or AC/DC
Adapter 9V/100mA (optional)
CALIBRATION
When to calibrate - calibration is RARELY required. Calibration may be required when the scale is first
set up for use, or if the scale is moved to a different altitude or gravitation. This is necessary because the
weight of a mass in one location is not necessarily the same in another location. Also, with time and use,
mechanical deviations can occur.
For the i500 you must have an accurate 500 gram weight or a combination of weights that equals 500
grams in order to calibrate.
For the i1200 there are 2 models:
For the 2003 i1200 you must have an
accurate 1200 gram weight or a combination of weights that equals 1200 grams in order to calibrate.
For the 2004 i1200 you must have an accurate 1000 gram weight or a combination of weights that
equals 1000 grams in order to calibrate. For the i2600 (2004-Current models) the correct calibration
weight is 2000 grams. For i2600 (2002 & 2003 models) the correct calibration weight is 2600 grams
Calibration Procedure:
1.
Before entering calibration mode, be sure the scale is powered OFF (must be OFF)