FEATURES

 

Auto shut off. Auto calibration 
Auto zero tracking and Auto backlight 
Low battery indication and 8 mode conversion 
Large LCD (6digits 15 mm high)  
Large square stainless steel weighing tray 
Net weight/stability indication 
0.1 gram division with professional accuracy  

PARTS DESCRIPTIONS

  

Side

 

AC adaptor 
Socket  

Top

 

Weighing platform: The arch face of platform is front, Correct the direction of the pan. 
Protectors: Remove these before use 
Display 
ON/OFF key: Turns the scale Power on/off. 
MODE key; Changes weighing units, g/oz/ozt/dwt/lb/gn/ct/n. ZERO key (for TARE): Sets display to zero 
or Subtracts weight of a container.  

Bottom

 

Battery compartment, Battery compartment cover, Batteries: Use 6 AA batteries 
Zero indicator: Indicates when the scale zero is correct. Weighing unit 
Stable indicator: Indicates when the reading is stable. 
Low battery indicator  

PREPARATION

  

Installing batteries/Connecting the AC adaptor

 

Remove the battery compartment and insert six Dry batteries(R6P/LR6/AA size) into the battery 
compartment. Use extreme care that the polarities plus and minus are correct.  

Plug the AC adapter to the AC adapter socket on the side. The AC input requirement could be 
100,120,220,230 or 240Volts (50/60Hz) depending on the area where used, so please verify that the 
adaptor is correct.  

Setting up the i500

 

Caution:

 Avoid placing the scale in direct sunlight, this may cause discoloration or malfunction. Place 

your i500/i1200 on a firm weighing table so that the scale is level. (The scale will not perform accurately 
when it is not level.) Make sure there are absolutely NO air currents or vibrations. They can cause 
inaccurate readings.  

Summary of Contents for I5500

Page 1: ...on You can use a paperclip to slightly bend the battery prongs to make them have a better connection Also some poorly designed batteries have recessed or partially obstructed battery terminals This may cause your prongs to be touching the plastic housing of the battery instead of the metal battery terminal A Faulty AC adaptor can cause your scale to act unstable with numbers jumping all around Ple...

Page 2: ... 24 Units in one box 48 48 22 cm3 Operating Temperature 0 40c 32 104f Power source 6 AA Size Batteries or AC DC Adapter 9V 100mA optional CALIBRATION When to calibrate calibration is RARELY required Calibration may be required when the scale is first set up for use or if the scale is moved to a different altitude or gravitation This is necessary because the weight of a mass in one location is not ...

Page 3: ...a given number of samples of an item on the pan the Sample Size should be either 10 20 50 or 100 pieces The weight of these samples will show on the display 4 Press the SET key several times to put the scale in PCS mode the indicator should be on pcs 5 Select the sample size the same as you chose above by pressing the PCS key press it as many times as necessary to put it in the correct sample size...

Page 4: ...tor Indicates when the scale zero is correct Weighing unit Stable indicator Indicates when the reading is stable Low battery indicator PREPARATION Installing batteries Connecting the AC adaptor Remove the battery compartment and insert six Dry batteries R6P LR6 AA size into the battery compartment Use extreme care that the polarities plus and minus are correct Plug the AC adapter to the AC adapter...

Page 5: ...yed and press ZERO Place the objects to be weighed in the container When the reading becomes stable the stable indicator is displayed FUNCTION SETTINGS 2003 Current models only 1 Enter function setting mode Press ON OFF to turn the power off Press Mode first then press ON OFF while keeping Mode pressed the display will show b_on arrow direct to light this means enter the selection of auto backligh...

Reviews: