GB
Thank you for purchasing our digital scale (KB-2000). With normal care and proper treatment, this scale will
provide years of reliable service.
General Maintenance and Care
1. Avoid exposure to extreme heat or cold. Also avoid any kind of moisture. Always allow your scale to
acclimate to normal room temperature before use.
2. Keep your scale in a clean and dry environment. Dust, dirt, moisture, vibration, air currents and proximity
to other electronic equipment may have an adverse effect on the accuracy and reliability of the scale.
3. Handle the scale with care. Gently apply all items to be weighed on the tray top. Although this scale is
designed to be quite durable, avoid rough treatment, as this may permanently damage the internal parts.
Always avoid shaking and dropping. This is a precision instrument and should be handled with extreme
care.
Specification and Function
1. Capacity: 2000g, Accuracy: 0.1g
2. Units: g, oz, dwt, ct
3. Key function: ON/OFF, TARE, MODE
4. Display: LCD display with backlight
5. Auto off: 180 seconds of inactivity.
6. Power: 2 AA batteries
7. Operation Temp: 10 to 30 deg C
Operation
1.
Place the scale on a leveled surface & press “ON/OFF” key to turn on the scale or power it off.
2. Wait until the LCD display shows zero, then press
“MODE” key to choose the weighing unit.
3. Put the object(s) on the weighing platform / bowl and wait until the reading is stable.
Tare Function
When using the bowl or another container to weigh, it is best to simply turn the scale on with the container
on the platform already. The scale should go to zero. Otherwise you can use the TARE function:
1. Turn on the scale as described above.
2. Place the “tare item” on the platform.
3.
Press “TARE” key and wait until the LCD displays zero.
4. Scale can now be used for
weighing. Add the “net-weight-item”.
Calibration
1. When the scale is turned off, press ON/OFF key to turn on the scale, until zero is displayed.
2.
Press and hold the “MODE” key until the display shows “CAL”, then release the button. Press “MODE”
key again, the required weight flashes on the display. Place the required weight onto the center of the
platform.
3.
The LCD display reads “PASS” and come back to the normal weighing mode. Calibration is now
complete.
Troubleshooting
The primary reasons for inaccuracy or malfunction are low batteries, incorrect calibration, overload or
operation on an unstable surface. Please keep this in mind and maintain & operate your scale properly.
Warning
1.
“LO”: Low voltage. Please replace the batteries.
2.
“O-Ld”: Overload. Please remove item quickly to protect the scale.