108
•
Operational Reference
Nano Series GigE Vision Camera
MaxInternal
MaxInternal Records the highest device temperature since
power up. Value is reset on power off.
Device Temperature
DeviceTemperature
The temperature of the selected source in
degrees Celsius. Maximum temperature
should not 70°C for reliable
operation.
1.00
Beginner
DALSA Software
Compatibility
Component List
DALSASoftwareCompatibilityComponentList List the optional Teledyne DALSA software
functions that are supported.
1.00
Beginner
TurboDrive 8-bit
requires v8.01
or greater
Compatibility1 Teledyne DALSA Turbo Drive 8-bit
(Monochrome or Bayer) requires Sapera-LT
8.01 or greater.
TurboDrive 10-bit
requires v8.10 or
greater
Compatibility2 Teledyne DALSA Turbo Drive 10-bit
(Monochrome or Bayer) requires Sapera-LT
8.10 or greater.
TurboDrive 12-bit
requires v8.10 or
greater
Compatibility3 Teledyne DALSA Turbo Drive 12-bit
(Monochrome or Bayer) requires Sapera-LT
8.10 or greater.
Multicast requires a
newer version
Compatibility4 Multicast feature support requires a newer
version of Sapera LT than currently installed.
UserSetDefaultSelector
Selects the camera configuration set to load
and make active on camera power-up or
reset. The camera configuration sets are
stored in camera non-volatile memory. (RW)
1.00
Beginner
Factory Setting
Default Load factory default feature settings.
UserSet1
UserSet1 Select the user defined configuration UserSet
1 as the Power-up Configuration.
UserSet2
UserSet2 Select the user defined configuration UserSet
2 as the Power-up Configuration.
UserSetSelector
Selects the camera configuration set to load
feature settings from or save current feature
settings to. The Factory set contains default
camera feature settings. (RW)
1.00
Beginner
Factory Setting
Default Select the default camera feature settings
saved by the factory.
UserSet 1
UserSet1 Select the User Defined Configuration space
UserSet1 to save to or load from features
settings previously saved by the user.
UserSet 2
UserSet2 Select the User Defined Configuration space
UserSet1 to save to or load from features
settings previously saved by the user.
Load Configuration
UserSetLoad
Loads the camera configuration set specified
by the User Set Selector feature, to the
camera and makes it active. Can not be
updated during a Sapera transfer. (W)
1.00
Beginner
Save Configuration
UserSetSave
Saves the current camera configuration to the
user set specified by the User Set Selector
feature. The user sets are located on the
camera in non-volatile memory. (W)
1.00
Beginner
Power-up Configuration
Selector
UserSetDefault
Specify the camera configuration set to load
and make active on camera power-up or
reset. The camera configuration sets are
stored in camera non-volatile memory.
1.00
Beginner
Serial Number
DeviceID
Displays the device’s factory set camera serial
number.
1.00
Invisible
Factory Setting
Default
Select the Factory Setting values as the
Power-up Configuration.
1.00
Invisible
UserSet1
UserSet1 Select the user defined configuration UserSet
1 as the Power-up Configuration.
Summary of Contents for C1240
Page 215: ...Nano Series GigE Vision Camera Operational Reference 205 ...
Page 275: ...Nano Series GigE Vision Camera Technical Specifications 265 Models M C4090 M C5100 ...
Page 276: ...266 Technical Specifications Nano Series GigE Vision Camera Models M C700 M C1450 ...
Page 277: ...Nano Series GigE Vision Camera Technical Specifications 267 Model M C1950 ...
Page 278: ...268 Technical Specifications Nano Series GigE Vision Camera Model C4900 ...
Page 297: ...Nano Series GigE Vision Camera Additional Reference Information 287 ...
Page 299: ...Nano Series GigE Vision Camera Additional Reference Information 289 ...