Nano Series GigE Vision Camera
Operational Reference
•
131
Line Format
LineFormat
Specify the current electrical format of the selected
physical input or output. (RO)
1.00
Expert
Opto-Coupled
OptoCoupled The line is opto-Coupled.
Line Mode
LineMode
Reports if the physical Line is an Input or Output
signal. (RO)
See Input Signals Electrical Specifications.
See Output Signals Electrical Specifications.
1.00
Expert
Input
Input The line is an input line.
Output
Output The line is an output line.
Line Status
LineStatus
Returns the current status of the selected input or
output line.
1.00
Expert
False The Line is logic LOW
True The Line is logic HIGH
Line Status All
LineStatusAll
Returns the current status of all available line
signals, at time of polling, in a single bitfield. The
order is Line1, Line2, Line3, ...
1.00
Expert
Line Inverter
LineInverter
Control to invert the polarity of the selected input
or output line signal.
1.00
Beginner
False / True
lineDetectionLevel
Specifies the voltage threshold required to
recognize a signal transition on an input line.
1.00
Beginner
DFNC
Threshold for TTL
Threshold_for_TTL A signal below 0.8V will be detected as a Logical
LOW and a signal greater than 2.4V will be
detected as a Logical HIGH on the selected input
line.
Input Line Debouncing
Period
lineDebouncingPeriod
Specifies the minimum delay before an input line
voltage transition is recognizing as a signal
transition.
1.00
Beginner
DFNC
outputLineSource
Selects which internal signal or event driven pulse
or software control state to output on the selected
line. Note, the LineMode feature must be set to
Output. The List of supported output line sources is
provides details and timing diagrams for the
supported trigger modes.
1.00
Beginner
DFNC
Off
Off Line output is Open
Software Controlled
SoftwareControlled The OutputLineValue feature changes the state of
the output
Pulse on: Start of Frame
PulseOnStartofFrame Generate a pulse on the start of the Frame Active
event
Pulse on: Start of Exposure
PulseOnStartofExposure Generate a pulse on the ExposureStart event. This
option is typically used to trigger a strobe light.
Pulse on: End of Exposure
PulseOnEndofExposure Generate a pulse on the ExposureEnd event. This
option is typically used to trigger a strobe light.
(N/A for C4900 – 1.06)
Pulse on: Start of Readout
PulseOnStartofReadout Generate a pulse on the ReadoutStart event.
Pulse on: End of Readout
PulseOnEndofReadout Generate a pulse on the ReadoutEnd event.
Pulse on: Valid Frame
Trigger
PulseOnValidFrameTrigger Generate a pulse on the ValidFrameTrigger event.
Pulse on: Rejected Frame(s)
Trigger
PulseOnInvalidFrameTrigger Generate a pulse on the InvalidFrameTrigger
event.
Pulse on: Start of Acquisition
PulseOnStartofAcquisition Generate a pulse when the AcquisiontStart event
occurs.
Pulse on: End of Acquisition
PulseOnEndofAcquisition Generate a pulse when the AcquisiontStop event
occurs.
Pulse on: End of Timer 1
PulseOnEndofTimer1 Generate a pulse on the TimerEnd 1 event.
Pulse on: End of Counter 1
PulseOnEndofCounter1 Generate a pulse on the CounterEnd 1 event.
Pulse on: Input 1 Event
PulseOnInput1 Generate a pulse on the Input signal 1 event
Summary of Contents for C1240
Page 215: ...Nano Series GigE Vision Camera Operational Reference 205 ...
Page 275: ...Nano Series GigE Vision Camera Technical Specifications 265 Models M C4090 M C5100 ...
Page 276: ...266 Technical Specifications Nano Series GigE Vision Camera Models M C700 M C1450 ...
Page 277: ...Nano Series GigE Vision Camera Technical Specifications 267 Model M C1950 ...
Page 278: ...268 Technical Specifications Nano Series GigE Vision Camera Model C4900 ...
Page 297: ...Nano Series GigE Vision Camera Additional Reference Information 287 ...