Random Invalid Trigger Events
•
Do not change the exposure time while grabbing, else an Invalid Trigger Event may be
generated. This applies to any exposure mode or trigger source. The Invalid Trigger Event is
not catastrophic and only indicates the loss of a video frame. Stopping acquisitions first will
avoid this error.
•
Version 1.00 firmware may not correctly generate Invalid Trigger Events when triggers are
received early (i.e. within the trigger exclusion period). All trigger management issues will
be resolved with firmware 1.01.
Minimum Sapera Version Required
Save User Configuration Failed: An unusual error that occurred with no other Nano control
problem. The solution is to verify the minimum Sapera version used with the Nano Framework. The
Genie Nano requires Sapera version 8.00 or later.
Issues with uninstalling Cognex VisionPro with Sapera LT CamExpert
When the Cognex VisionPro package is uninstalled, the Genie Nano becomes not available within
CamExpert due to the Cognex uninstaller removing GigE Vision components. This forces a Genie
Nano user to reinstall the Network Imaging package (or execute a repair within Sapera LT).
Cognex VisionPro remains a useable third party product except for their uninstaller fault. Genie
Nano users just need to account for this issue until resolved by Cognex.
Summary of Contents for C1240
Page 215: ...Nano Series GigE Vision Camera Operational Reference 205 ...
Page 275: ...Nano Series GigE Vision Camera Technical Specifications 265 Models M C4090 M C5100 ...
Page 276: ...266 Technical Specifications Nano Series GigE Vision Camera Models M C700 M C1450 ...
Page 277: ...Nano Series GigE Vision Camera Technical Specifications 267 Model M C1950 ...
Page 278: ...268 Technical Specifications Nano Series GigE Vision Camera Model C4900 ...
Page 297: ...Nano Series GigE Vision Camera Additional Reference Information 287 ...
Page 299: ...Nano Series GigE Vision Camera Additional Reference Information 289 ...