64
•
Operational Reference
Linea Lite GigE Series Camera
Line Format
LineFormat
Specify the current electrical format of the selected
physical input or output. Applies to all physical lines. (RO)
Expert
RS422
RS422
The line accepts or sends RS422 level signals.
Single Ended
SingleEnded
The line is single ended input for 3.3V/5V/12V/24V or
output for 3.3V LVTTL
Line Mode
LineMode
Reports if the physical Line is an Input or Output signal.
(RO)
See Input Signals Electrical Specifications.
See Output Signals Electrical Specifications.
Expert
Input
Input
The line is an input line.
Output
Output
The line is an output line.
Line Status
LineStatus
Returns the current status of the selected input or output
line. (RO)
Expert
False / True
Line Inverter
LineInverter
Controls whether to invert the polarity of the selected
input or output line signal.
Beginner
False / True
Input Line Detection Level
lineDetectionLevel
Specifies the voltage threshold required to recognize a
signal transition on an input line.
Expert
DFNC
Threshold for TTL
Threshold_for_TTL
A signal below 0.8V will be detected as a Logical LOW and
a signal greater than 2.4V will be detected as a Logical
HIGH on the selected input line.
Input Line Debouncing
Period (in
μs)
lineDebouncingPeriod
Specifies the minimum delay before an input line voltage
transition is recognizing as a signal transition.
Beginner
DFNC
outputLineSource
Selects which internal signal or event driven pulse or
software control state to output on the selected line. Note,
the LineMode feature must be set to Output. The List of
supported output line sources is product-specific. The
provides details and timing diagrams
for the supported trigger modes.
Beginner
DFNC
Off
Off
Line output is Open
Software Controlled
SoftwareControlled
The
feature changes the state of the
output
Pulse on: Start of Frame
PulseOnStartofFrame
Generate a pulse on the start of the Frame Active event
Pulse on: Start of Line
PulseOnStartofLine
Generate a pulse on the start of the Line Active
Pulse on: Start of Exposure
PulseOnStartofExposure
Generate a pulse on the ExposureStart event. This option
is typically used to trigger a strobe light.
Pulse on: Rejected Trigger
PulseOnInvalidTrigger
Generate a pulse on the Invalid Trigger event.
Pulse on: End of Exposure
PulseOnEndofExposure
Generate a pulse on the ExposureEnd event. This option is
typically used to trigger a strobe light.
Pulse on: Valid Line Trigger
PulseOnValidLineTrigger
Generate a pulse on the LineTrigger event.
Pulse on: Invalid Line
Trigger
PulseOnInvalidLineTrigger
Generate a pulse on the Invalid LineTrigger event.
Pulse on: End of Timer 1
PulseOnTimer1End
Generate a pulse on the TimerEnd 1 event.
Pulse on: End of Counter 1
PulseOnCounter1End
Generate a pulse on the CounterEnd 1 event.
Pulse on: Input 1 Signal
PulseOnInput1
Generate a pulse on the Input signal 1 event
Pulse on: Input 2 Signal
PulseOnInput2
Generate a pulse on the Input signal 2 event
Output Line Pulse Signal
Activation
outputLinePulseActivation
Specifies the input line activation mode to trigger the
OutputLine pulse.
Beginner
DFNC
Rising Edge
RisingEdge
Specifies that the trigger is considered valid on the rising
edge of the source signal.
Falling Edge
FallingEdge
Specifies that the trigger is considered valid on the falling
edge of the source signal.
Any Edge
AnyEdge
Specifies that the trigger is considered valid on the falling
or rising edge of the source signal.
Preliminary