Linea Lite GigE Series Camera
Operational Reference
•
69
Timer Start Source
timerStartSource
Select the trigger source to start the timer. The
provides details and timing diagrams for
the supported events.
Expert
DFNC
TimerReset Cmd
Off Starts with the reception of the TimerReset Icommand.
Acquisition Start
AcquisitionStart Start Timer on Acquisition Start event.
Exposure Start
ExposureStart Start Timer on Exposure Start event.
Frame Start
FrameStart Start Timer on Frame Start event.
Line 1
Line1 Start Timer on a transition of I/O Line 1 event.
See Input Signals Electrical Specifications.
Line 2
Line2 Start Timer on a transition of I/O Line 2 event.
Timer 1 End
Timer1End Start Timer on Timer 1 End event.
Counter 1 End
Counter1End Start Timer on Counter 1 End event.
Timer Line Activation
timerStartLineActivation
Select the trigger activation mode which starts the timer.
Expert
DFNC
Rising Edge
RisingEdge Starts counter on rising edge of the selected signal.
Falling Edge
FallingEdge Starts counter on falling edge of the selected signal.
Any Edge
AnyEdge Starts counter on the falling or rising edge of the
selected signal.
Timer Duration (in
μ
s)
timerDuration
Sets the duration (in microseconds) of the timer pulse.
Expert
DFNC
Timer Value
timerValue
Reads the current value (in microseconds) of the selected
timer.
Expert
DFNC
Timer Reset
timerReset
Resets the timer to 0.
Expert
DFNC
Counter and Timer Group Block Diagram
Line Selector =
Line 1 to 6
Physical
Line
Event Driven
Input
Inverter
Output
inverter
Software Driven
Pulse
Generator
LineStatus
Trigger
Line
Activation
Trigger Signal
Timer
TimerEnd Event
CounterEnd Event
Software Trigger
Cmd
Line
Mode
Input
or
Output
Input
Output
Timer and Counter Module
Counter
Line
Debouncer
Event Driven
Trigger
Source
Trigger Module
Output
Line
Source
Signal Driven
Software Driven
Line
Detection
Level
Preliminary