68
•
Operational Reference
Linea Lite GigE Series Camera
Counter Reset Source
counterResetSource
Selects the signal source to reset the counter then waits
for the next countStartSource signal or event.
Expert
DFNC
Reset Cmd
Off Reset on reception of the Reset Icommand.
Acquisition Start
AcquisitionStart Reset on reception of the Acquisition Start.
Acquisition End
AcquisitionEnd Reset on reception of the Acquisition End.
Exposure Start
ExposureStart Reset on reception of the Exposure Start event.
Exposure End
ExposureEnd Reset on reception of the Exposure End event.
Readout Start
ReadoutStart Reset the counter on the reception of the Readout Start
event.
Readout End
ReadoutEnd Reset the counter on the reception of the Readout End
event.
Frame Trigger
FrameStart Reset on reception of the Frame Trigger event.
Valid Frame Trigger
ValidFrameTrigger Reset on reception of the Valid Frame Trigger event.
Rejected Frame Trigger
InvalidFrameTrigger Reset on reception of the Invalid Trigger event.
MultiFrame End Trigger
FrameBurstEnd Reset on reception of the Frame Burst end event.
Line 1
Line1 Reset counter on the specified transition on line 1.
See Input Signals Electrical Specifications.
Line 2
Line2 Reset counter on the specified transition on line 2.
Timer 1 End
Timer1End Reset on reception of the Timer 1 End.
Counter 1 End
Counter1End Reset on the reception of the Counter 1 end.
Counter Reset Input Line
Activation
counterResetLineActivation
Specify the edge transition on the selected line that will
reset the selected counter.
Expert
DFNC
Rising Edge
RisingEdge Reset counter on rising edge of the selected signal.
Falling Edge
FallingEdge Reset counter on falling edge of the selected signal.
Any Edge
AnyEdge Reset counter on the falling or rising edge of the selected
signal.
Counter Duration
counterDuration
Sets the duration (or number of events) before the
CounterEnd event is generated.
Expert
DFNC
Counter Value
counterValue
Read the current value of the selected counter. (RO)
Expert
DFNC
Counter Value At Reset
counterValueAtReset
Reads the value of the selected counter when it was reset
by a trigger or by an explicit Counter Reset command.
(RO)
Expert
DFNC
Counter Reset
counterReset
Resets the selected counter to zero. The counter starts
immediately after the reset. To temporarily disable the
counter, set the Counter Event Source feature to Off.
(WO)
Expert
DFNC
Timer Selector
timerSelector
Selects which timer to configure.
Expert
DFNC
Timer 1
Timer1 Configure Timer 1.
Timer 2
Timer2 Configure Timer 2.
Timer Mode
timerMode
Select the timer mode. The selected Timer is Active or
Disabled. When Disabled, the Timer can be configured.
Expert
DFNC
Off
Off The selected Timer is Disabled.
Active
Active The selected Timer is Enabled.
Timer Status
timerStatus
Returns the current state of the timer. (RO)
Expert
DFNC
Timer Idle
TimerIdle The timer is idle. The CounterStartSource feature is
set to off.
Timer Trigger Wait
TimerTriggerWait The timer is waiting for a start trigger.
Timer Delaying
TimerDelaying The timer is counting the requested delay.
Timer Active
TimerActive The timer is counting for the specified duration.
Timer Completed
TimerCompleted The timer reached the TimerDuration count.
Preliminary