100
PRELIMINARY
Spyder 3 CL User's Manual
03-032-20008-03
DALSA
Dark Current Dump to Immediate Readout (T
INT
> #)
T
VERT_TRANS
F
DUMP
LVAL
F
IMMEDIATE
Valid
EXSYNC
T
DUMP
T
INT
Dark Current Dump to Immediate Readout: Multi-Line Artifacts
SRM 0, Auto Mode.
Time Period
Operating Region
Refer to Figure 29.
Operating Mode
T
0
Dark Current Dump state
T
1
Immediate Readout state
SRM 0, Auto Mode.
Time Period
Operating Region
Refer to Figure 29.
Operating Mode
T
0
Immediate Readout state
T
1
Dark Current Dump state
T
2
Immediate Readout state
SRM 2, Immediate Readout Mode.
Time Period
Operating Region
Refer to Figure 29.
Operating Mode
T
0
Dark Current Dump state
T
1
Immediate Readout state
Summary of Contents for Spyder 3 S3-10-01k40-00-R