52
PRELIMINARY
Spyder 3 CL User's Manual
03-032-20008-03
DALSA
Setting the Line Rate
Purpose:
Sets the camera’s line rate in Hz. Camera must be operating in
exposure mode 2 or 7.
Syntax:
ssf f
Syntax Elements:
i
Desired line rate in Hz. Allowable values are:
1k 1 tap:
300
-
36000
Hz
1k 2 tap:
300
-
68000
Hz
2k 1 tap:
300
-
18500
Hz
2k 2 tap:
300
-
36000
Hz
4k 2 tap:
300-18500
Hz
Notes:
•
To read the current line frequency, use the command
gcp
or
get
ssf
.
•
If you enter an invalid line rate frequency, an error message is
returned.
Related Commands:
sem
,
set
Example:
ssf 10000
Setting the Exposure Time
Purpose:
Sets the camera’s exposure time is µs. Camera must be operating in
mode 2, 6, or 8.
Syntax:
set f
Syntax Elements:
i
Desired exposure time in µs. Allowable range is
3
to
3300
µs.*
Notes:
•
To read the current line frequency, use the command
gcp
or
get set
.
•
If you enter an invalid line rate frequency, an error message is
returned.
•
*The exposure time range is based on the current line rate.
•
To determine the maximum exposure time allowed for the
current line rate, use the command
get ger
.
Related Commands:
sem
,
ssf
Example:
set 400.5
Setting the Mirror Mode
Purpose:
Sets the camera’s mirror mode. Set the pixel readout as either left to
right, or right to left.
Syntax:
smm i
Syntax Elements:
i
0
: Pixels readout left to right.
1
: Pixels readout right to left.
i
Applies to Modes 2 and
7
i
Applies to Modes 2 and
8
Summary of Contents for Spyder 3 S3-10-01k40-00-R
Page 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...