8
PRELIMINARY
Spyder 3 CL User's Manual
03-032-20008-03
DALSA
Table
3:
Camera
Operating
Specifications
Specifications
Unit
-10dB
0dB
+10dB
Min
Typ
Max Min
Typ
Max Min Typ
Max
Broadband
responsivity
DN/(nJ/cm²)
Dual
line
652.8
2064
6528
Single
line
326.4
992
3264
4k Dual line
326.4±2
1032±5
3264±16
4k Single line
163.2±2
516.8±5
1632±16
Random noise rms
DN
3
6.5
9.2
20.5
30
65
Dynamic range
DN:DN
Dual
line
500:1 1400:1
203:1 324:1
59:1 108:1
Single
line
500:1 1400:1
203:1 324:1
59:1 108:1
4k Dual and Single
160:1
160:1
160:1
FPN global
DN p-p
Uncorrected
52.8
169.6
536
Corrected
32
32
64
PRNU ECD
Uncorrected
local %
8.5
8.5
11.5
Uncorrected global %
10
10
10
Corrected
local
DN p-p
80
80
95
Corrected
global
DN p-p
80
80
95
PRNU ECE
Uncorrected
local %
8.5
12
37
Uncorrected global %
10
12
37
Corrected
local
DN p-p
80
237
752
Corrected
global
DN p-p
80
208
752
SEE (calculated)
nJ/cm²
Dual
line
6.35
1.92
0.61
Single
line
12.2
4.0
1.2
NEE (calculated)
pJ/cm²
Dual
line
4.6
4.5
4.6
Single
line
9.2
9.3
9.2
Saturation output
amplitude
DN
3968±80
DC offset
DN
96
160
336
Test conditions unless otherwise noted:
•
12-bit values, Flat Field Correction (FFC) enabled.
•
CCD Pixel Rate: 40 Megapixels/second per sensor tap.
•
Line Rate: 5000 Hz.
•
Nominal Gain setting unless otherwise specified.
•
Light Source: Broadband Quartz Halogen, 3250k, with 750 nm highpass filter
installed.
•
Ambient test temperature 25 °C.
•
Unless specified, all values are referenced at 12 bit.
Summary of Contents for Spyder 3 S3-10-01k40-00-R
Page 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...