Spyder 3 CL User's Manual
PRELIMINARY
91
DALSA
03-032-20008-03
Mnemonic
Syntax Parameters Description
restore user settings
rus
Restores the camera's last saved user
settings and FPN and PRNU
coefficients.
set analog gain
sag
t f
Sets the analog gain in dB.
t
= tap selection, either
1
or
2
depending on camera model, or
0
for
all taps.
f
= gain value specified from
–10
to
+10
set analog offset
sao
t i
Sets the analog offset.
t
=
tap selection, either
1
or
2
depending on camera model, or
0
for
all taps.
i
= Offset value in a range from
0
to
255
(12-bit LSB). Offset increases with
higher values.
set binning horizontal
sbh
m
Sets the horizontal binning value.
Available values are
1
and
2
.
set baud rate
sbr
i
Set the speed of camera serial
communication port. Baud rates:
9600
,
19200
,
57600
, and
115200
. Default:
9600.
set cable parameter
scb
i
Set the cable parameter. Output
compare value. Available values are: 0-
255.
set ccd direction
scd
i
Sets the CCD shift direction where:
0 =
Forward CCD shift direction.
1 =
Reverse CCD shift direction.
2 =
Externally controlled direction
control via CC3. (CC3=1 forward,
CC3=0 reverse.)
set digital offset
sdo
t i
Subtracts the input value from the
video signal prior to FPN correction.
t
= tap selection, either
1
or
2
depending on camera model, or
0
for
all taps.
i
= Offset in a range from
0
to
2048
DN.
Summary of Contents for Spyder 3 S3-10-01k40-00-R
Page 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...