92
PRELIMINARY
Spyder 3 CL User's Manual
03-032-20008-03
DALSA
Mnemonic
Syntax Parameters Description
set exposure mode
sem
m
Sets the exposure mode:
2 =
Internal SYNC, internal PRIN,
programmable line rate and exposure
time using commands
ssf
and
set
3 =
External SYNC, internal PRIN,
maximum exposure time
4
= Smart EXSYNC
5
= External SYNC and PRIN
6
= External SYNC, internal PRIN,
programmable exposure time
7 =
Internal programmable SYNC,
maximum exposure time. Factory
setting.
8
= Internal SYNC, internal PRIN,
programmable exposure time.
Maximum line rate for exposure time.
set exposure time
set
f
Sets the exposure time. Refer to the
camera help screen (
h
command) for
allowable range.
set fpn coeff
sfc
x i
Set the FPN coefficient.
x
=pixel number within the range
1
to
sensor pixel count
.
i
= FPN value within the range
0
to
2047
(12-bit LSB).
set input LUT
sil
t i
Set a single value in a LUT.
t
=Tap: 1 or 2.
i
=Value within the range -255 to +256.
set lower threshold
slt
i
The pixels below the lower threshold
are checked for and reported in the
end-of-line sequence in a range from
0
-
4095
.
set prnu coeff
spc
x i
Set the PRNU coefficient.
x
=pixel number within the range
1
to
sensor pixel count
.
i
= PRNU value within the range
0
to
28671
.
set readout mode
srm
i
Set the readout mode in order to clear
out dark current charge in the vertical
transfer gates before the sensor is read
out.
0
= Auto.
1
= Dark current clear.
2
= Immediate readout. Does not clear
dark current.
Summary of Contents for Spyder 3 S3-10-01k40-00-R
Page 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...