Spyder 3 CL User's Manual
PRELIMINARY
97
DALSA
03-032-20008-03
S3-10-02k40 7.05KHz
8.52KHz
S3-20-02k40 13.6KHz
16.4KHz
S3-20-04k40 7.05KHz
8.52KHz
Immediate read out mode (default, srm 2)
In this mode the image is read out, including accumulated dark current, immediately
following the trigger or the EXSYNC falling edge.
There are no line rate limitations other than the amount of gate dark current that can be
tolerated at low line rates.
There are no timing or exposure anomalies other than situations where EXSYNC is
removed from camera. In this case, the camera will operate in a "watchdog" state.
For information on artifacts that may be experienced while using this mode, see the
Artifacts section below.
Gate dark current clear mode (always on, srm 1)
In this mode the gate dark current will be cleared continuously.
After the trigger (EXSYNC) is received, the dark current is cleared from the image sensor
before the image is acquired. The line rate is limited to ½ the maximum line rate available
for that model of camera.
For information on artifacts that may be experienced while using this mode, see the
Artifacts section below.
Table 18.
Max. Line Rate
Model Immediate
Readout
Mode
Dark Current Clear
Mode
S3-10-01k40 36
KHz
18KHz
S3-20-01k40
68 KHz
34 KHz
S3-10-02k40 18.5KHz
9.25KHz
S3-20-02k40
36 KHz
18 KHz
S3-20-04k40 18.5KHz
9.25KHz
When operating in the dark current clear mode, there will be a slight delay,
equivalent to one readout time, before the actual exposure is implemented. The
actual exposure time will not be altered.
Table 19.
Model
Exposure Delay and Max Exposure Time in Auto
Mode
S3-10-01k40 27.5
µs
S3-20-01k40 14.75
µs
S3-10-02k40 53.1µs
S3-20-02k40 27.5
µs
S3-20-04k40 53.1µs
Summary of Contents for Spyder 3 S3-10-01k40-00-R
Page 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Page 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...