X64-AN Quad User's Manual
Sapera LT
87
from the camera. The type of external trigger signal is dependent on the capabilities of the frame
grabber hardware.
For setup and testing purposes CamExpert provides a control button to simulate the asynchronous
event trigger. This software trigger control simplifies the camera configuration and testing procedure
before the vision system is placed into its final location.
JAI CV-A11 Control Setting
The following screen image shows the camera setup for Edge Pre-select trigger which is selected from
the Trigger Mode drop menu. The shutter mode can either be normal or programmed exposure. The
scan mode can be full or partial as required.
Figure 47: Setting the JAI CV-A11 to a Trigger Mode
CamExpert Settings
CamExpert parameters are in two groups—those which select the control method and those which
enable one of the possible control methods.
First select a Sapera camera trigger method that matches the trigger timing required by the camera.
In this example with the JAI CV-A11, Sapera camera trigger method 1 is selected.