X64-AN Quad User's Manual
Sapera LT
91
step 4: JAI CV-A11 in Time Integration Mode
The JAI CV-A11 trigger mode Pulse Width Control is a single pulse time integration mode. The
leading edge of the trigger initiates the video capture while the trigger pulse width determines the
exposure time.
JAI CV-A11 Control Setting
The following screen image shows the camera setup for Pulse Width Control trigger which is selected
from the Trigger Mode drop menu. Camera shutter speed is not applicable in this mode.
Figure 53: CamExpert: Pulse Width Trigger Setup
CamExpert Settings
CamExpert parameters are in two groups similar to the previous example. Those which select the
control method and those which enable one of the possible control methods.
First select a Sapera time integration method that matches the timing and control required by the
camera. In this example with the JAI CV-A11, time integration method 1 is selected.