6 . I N S P E CTI O N AN D MAI N T E NANCE
6.3 BATTERY, FUSE AND TYRE
■
Battery
Refer to the section entitled “5.2 BATTERY” in “5. BATTERY CHARGING AND CARE”.
■
Fuse
If the battery charger is turned on and no LEDs are lit, check the fuse.
Suggestion
Ask for help from your scooter dealer to inspect or replace the fuse, since the tiller shroud has to be
removed first before you can replace the fuse.
▓
Tires
The condition of the tires depends on how you drive and use your scooter.
Inspecting tire tread
Please check the tread groove regularly. Replace the tires when the tread groove is less than 0.5 mm.
Attention
1
.
When tread groove is below 0.5mm it can easily lead to vehicle slippage, making braking
distances longer. Therefore replace the tires as early as possible when they do not have
insufficient tread depth.
2
.
The tire pressure shall be kept at about 26 PSI (approx. 1.8KG/cm) for the best ride and handling.
Attention
When conducting maintenance of your vehicle, please turn the power switch to OFF and remove the
charger cords.
Suggestions
Do not splash water directly to wash your scooter as this could lead to malfunction of the system
electrics.
Do not use petrol, solvents or vaporizing solution as these may deform or damage the shrouds.
Do not use wax.
6.4 STORAGE
Make sure the vehicle is stored under the following circumstances:
-
Make sure the seat is set in the “Forward
”
position
-
Make sure the Power switch is turned to OFF
Suggestion
Please store the scooter in a location where it is away from the direct sunlight, rain, or dew. When
storing for a long time, please charge the battery to full power and then disconnect the battery
terminal. For details inquire to your scooter dealer.