23
CHOOSE PROGRAM
Preparations
Before starting a measurement, there are several things that are good to check to
ensure a good and accurate measurement.
• Ensure a good measurement environment. Strong sunlight, warning lights, vibra-
tions and temperature gradients can affect the readings.
• Make sure the surfaces are clean.
• Ensure that the foundation of the machine is stable.
• Check for play and clearance in the bearing.
Vertical
For alignment of vertically mounted machines.
9-12-3. Measuring positions are registered at positions 9, 12, 3 o’clock.
EasyTurn™. Measuring positions are registered within 40º.
Horizontal
For alignment of horizontal machines.
Values
Shows live readings from S and M units.
Softfoot
Check to ensure that the machine is resting evenly on all its feet.