43
SOFTFOOT
Perform a softfoot check to ensure that the machine is resting evenly on
all its feet. A softfoot can be angular and/or parallel, see image.
Softfoot can be caused by:
• Twisted machinery foundations.
• Twisted or damaged machinery feet.
• Improper amount of shims under machine feet.
• Dirt or other unwanted materials under machine feet.
Start Softfoot from main shaft menu
1. Select
and
.
2. Enter distances.
3. Select
to continue.
Start Softfoot from Horizontal program
1. Select
and
to open Horizontal program.
2.
Enter distances. Confirm each distance with
OK
. To perform a Softfoot check,
you need to enter distances between the feet pairs. The measure view is displayed.
3. Select
. Softfoot is only available before you have registered any measure-
ment points.
Function buttons
Leave program.
See
Add a feet pair.
Continue to Measure view. Available when you have entered the distances.
Angular softfoot
Parallel softfoot