45
VERTICAL
The program Vertical is used for vertical and/or flange mounted machines.
Preparations
1. Mount the M-unit on the movable machine and the S-unit on the stationary
machine.
2. Select
and
to open Vertical program.
3.
Enter distances. Confirm each distance with
.
If you have a barcode reader, simply scan the barcode and all machine data is read.
“Measurement file handling” on page 11
Function buttons
Leave program
.
See
Select to enter diameter of coupling.
Forward to measure view.
1
Distance between S-unit and M-unit.
Measure between the rods.
Mandatory
.
2
Distance between S-unit and centre of coupling.
Mandatory
.
3
Number of bolts (4, 6 or 8 bolts).
4
Bolt circle diameter (centre of the bolts).
5
Coupling diameter. Select
to activate field.
3
1
4
5
2
www.
GlobalTestSupply
.com
Find Quality Products Online at:
sales@GlobalTestSupply.com
Summary of Contents for Easy-Laser E420
Page 2: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Page 26: ...22 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Page 28: ...24 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Page 34: ...30 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...
Page 58: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...