background image

L

N

4

5

CONNECTION:

A.

  

Connect Live wire (red or brown) to the terminal 

block marked ”L”

B.

  

Connect Neutral wire (blue) to the terminal block 

marked ”N”

C.

  

Connect Ground wire (green and yellow) to terminal 

block marked ”    ”

WARNING

• All units must be equipped with a 3-wire service. Connect the ground wire according to the  
 instructions.

• This product must be installed only by qualified persons. Use 2.0 mm2 (AWG) NO.14 wiring.

• Turn off the power to the unit before servicing or cleaning. All wires must be disconnected.
• Incorrect installation, defect power cords, or failure to properly ground unit could result in
  electrical shock or life-threatening injuries

NOTE

 

We do not recommend to install this product less than 300 mm above washbasin, tabletop or

other surface. This product is suitable for indoor use only.

Type Y connection: If the power supply cord is damaged, it must be replaced immediately.

Only qualified persons shall be permitted to replace the cord to avoid a hazard. Disconnect the

electricity supply cord according to instructions.

This product is not intended for use by persons (inclusive children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they are

supervised or have been given instruction concerning use of the product by a person

responsible for their safety.

Children should be supervised to ensure this product is used correctly.

GENERAL SAFETY INFORMATION

INSTALLATION

CIRCUIT DIAGRAM

• Make sure the main breaker is turned off. Installation must be carried out by  

  a qualified person in accordance with standards applicable in the country where the  

  equipment is to be installed.

• Place template against the wall at desired height (see mounting height  

 

 recommendations).

!

NOTE 

Colours of live and neutral wires depend on the 

supply voltage.

5. Connect supply wires to terminal block:

1. Dismount the casing by removing the 2 

securing screws.

3. Attach the base plate of the hand

dryer to the wall with the screws

supplied with the unit

  

4. Insert the power cord through the inlet hole. 

Fasten with the retaining clip

2. Place the template 

on the wall

at the desired location 

(see recommended 

installation height). 

Drill (4) holes as 

indicated.

Summary of Contents for 288

Page 1: ...2 USER MANUAL STAINLESS DESIGN TURBO HAND DRYER Model 288 249 ...

Page 2: ...PE MODEL 288 249 Stainless steel TURBO Design hand dryer 230V 110V IMPORTANT This product falls within the scope of the WEEE directive on recycling and recovery of waste electrical and electronic equipment This product should not be disposed of with general household waste This product must be reused if possible Contact your local authority for further details This product may also be returned to ...

Page 3: ...supply cord according to instructions This product is not intended for use by persons inclusive children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are supervised or have been given instruction concerning use of the product by a person responsible for their safety Children should be supervised to ensure this product is used correctly GENERA...

Page 4: ...tom of the sink Be careful not to overturn the sensivity adjustment RECOMMENDED INSTALLATION HEIGHT From bottom edge of hand dryer above finished floor Men 1270 mm 50 Women 1194 mm 47 Children 4 7 years 889 mm 35 Children 8 10 years 991 mm 39 Children 11 13 years 1092 mm 43 Children 14 16 years 1194 mm 47 Wheelchair users 1016 mm 40 PRODUCT APPLICATION Shake excess water from hands Place hands und...

Page 5: ...andomly and stops before the cycle is finished Check timer and sensor Replace if required The hand dryer runs but the airspeed is low Ensure the voltage is correct Check setting of potentiomenter for air speed adjust ment see page 7 SYMPTOM CORRECTIVE ACTION USED HAND DRYER Hand dryer does not start Check power supply to the product and ensure the connections at the terminal block are made properl...

Page 6: ...DAN DRYER A S Alsikevej 8 DK 8920 Randers NV T 45 8641 5711 E info dandryer com W dandryer com ...