Installation Guide
CONFIDENTIAL
TG-0057_19 TM4 SUMO HD CO300-A1_A2_A2.5 Installation Guide
© Dana TM4 inc., 2013-2020
Page 41 of 42
2020-11-20
Base Address ID
Related messages
Base range
length
Default base
range
Can1BaseAddr4
Customer specific messages
(CAN extension pack)
8
0x0450-
0x0457
Table 17
CAN diagnostic interface (CAN 2) base ranges
Base Address ID
Related messages
Base range
length
Default base
range
Can2BaseAddr1
TM4 diagnostic tool messages
(TM4 ODIN)
32
0x0680-
0x069F
Can2BaseAddr2
Diagnostic messages (E.g. UDS)
8
0x0710-
0x071F
4.6.2.2 Reconfiguring the CAN bus baud rate
The CAN bus baud rate can be configured at the following speeds: 125 kb, 250 kb, 500 kb and 1 Mb. The
default CAN baud rate is 500 kb.
Before reconfiguring the speed, ensure that your software versions are as follows:
•
Bootloader: v1.6.1.56671 or later.
•
TM4 ODIN: v4.12.0.x or later.
Note
: Earlier versions do not support baud rate configuration.
1
To change baud rate, select the desired SPEED_OPTION in
Parameters:Drive:CanBaudRate
in TM4
ODIN.
2
Save the new value with the
Parameters:.Command:DrvParameters.Save
command.
Note
: The system must be shut down and then restarted for the changes to be effective.
3
Before being able to connect the device with TM4 ODIN, you need to modify the CAN communication
speed in TM4 ODIN (
Configuration/Device Communication
) for it to match the new value that you
configured in step 2.
4.6.3 Embedded software packages
The software installation package, provided to the customer, includes two files: the embedded software
package executable and a basic TM4 ODIN file (.odn4).
Table 18
Embedded software package files
File
Name
Description
Embedded software
Package executable
MCU_INVHP2HV_0309_MOTOR_INFO_
v*_*_*_*_Pkg.exe
Copy of the embedded software
files used for firmware update.
Basic TM4 ODIN file
MCU_INVHP2HV_0309_MOTOR_INFO_
v*_*_*_*_.odn4
Basic file used within TM4 ODIN to
see software variables.
Note
: TM4 product software package names may be subject to change.
The executable is used to copy the necessary files to update the MCU firmware while the .odn4 file can be
loaded from TM4 ODIN for diagnostic purposes.