Istruzioni assemblaggio – Assembly instructions  

Serie DT – MR – MW – MC – MS – FP  

 

           MK – VT – P1509 – P1507 – TP – TPS – TPM 

DOC00032.doc Rev. D 

5/8

 

Proprietà dell’azienda Dana Incorporated vietata qualsiasi riproduzione anche parziale senza l’autorizzazione della stessa.        ISTRUZIONI ORIGINALI 
Property of Dana Incorporated. Reproduction in whole or in part without express written consent is prohibited.                       ORIGINAL INSTRUCTIONS 

 

I  dati  riportati  sono  frutto  di  esperienza  e  test  di  laboratorio,  e  tengono 
conto  di  fissaggi  essenziali  alle  macchine  o  attrezzature  con  medie 
vibrazioni (trans pallet in ambiente da officina).  
 
 
INSTALLAZIONE 

Durante  l’installazione  preoccuparsi  della  massima  pulizia 
effettuando  le  principali  operazioni  di  collegamento  in  un  locale 

pulito e non polveroso. 

La UP deve essere montata in posizione ergonomica in modo tale 
da  permettere  una  facile  accessibilità  alle  ispezioni  e  alla 

manutenzione. È altrettanto indispensabile che essa venga montata in una 
zona protetta da urti accidentali e riparata da casuali contatti fisici, poiché 
la  temperatura  raggiunta  durante  il  funzionamento  può  essere  causa  di 
ustioni. 

La  UP  deve  essere  fissata  saldamente  alla  macchina  nei  punti  di 
maggiore  resistenza  (es:  telaio  portante,  longheroni,  ecc..),  lontano 
da  qualsiasi  fonte  o  parte  di  macchina  che  possano  vibrare, 

trasmettere o amplificare rumore e vibrazioni. 
La UP con serbatoio in plastica deve essere applicata in ambienti protetti 
da esposizione ai raggi solari e con limitate escursioni termiche.

 

 

La  UP  deve  essere  fissata  con  i  due  fori  ISO  M10  presenti  sul  corpo  in 
alluminio.  Le  stesse  UP  sopra  descritte  si  possono  fissare  con  l’  utilizzo 
dell’  apposito  piedino  fornito  a  richiesta.  Su  macchine  fisse    (posizione 
orizzontale o verticale) i limiti di peso consigliati per il fissaggio con i 2 fori 
M10 sono: 

 

con motore AC B14 Grandezza 112 

 

con serbatoio 10 L 

 

con serbatoio 12 L utilizzando anche i piedi del serbatoio stesso. 

Sulle  macchine  mobili  (prediligere  posizione  verticale  e  fissare  vicino  al 
baricentro) i limiti di peso consigliati per il fissaggio con i 2 fori M10 sono: 

 

con tutti i  motori DC 

 

con serbatoi 6 L in lamiera 

 

con serbatoi 5 L in plastica PP 

 

con serbatoi 4 L in plastica PE 

 
Se l’Utilizzatore analizza la propria applicazione si possono applicare alle 
UP    serbatoi  di  capacità  superiore  ancorando,  per  esempio,  anche  lo 
stesso serbatoio alla struttura del mezzo mobile. 
Norme generali per una corretta installazione 

Prendere  visione  dello  schema  oleodinamico  e  dell’eventuale 
schema  elettrico  (il  nostro  ufficio  tecnico/commerciale  è  a  Vostra 
disposizione per qualsiasi spiegazione). 
Evitare di asportare i tappi in plastica di protezione fino al momento 
del collegamento dei tubi. 
Alcune  valvole  ad  intervento  elettrico  sono  munite  di  emergenza 
manuale  a  vite,  tale  emergenza  deve  sempre  essere  disattivata 
prima di rimettere in funzione l’ impianto. 
Per  UP  con  blocchi  modulari  CETOP  utili  per  il  collegamento  di 
elettrodistributori,  utilizzare  per  i  fori  di  attacco  raccordi  cilindrici 
secondo  la  normativa  DIN  3852  e  le  filettature  in  accordo  con  le 

normative UNI-ISO 228. 

Si  ricorda  che  l’avvitamento  di  raccordi  (in  acciaio)  con 
ammaccature  sul  filetto  maschio  provoca  una  asportazione  di 
truciolo  nella  sede  femmina  (in  alluminio)  causa  principale  del 

difettoso funzionamento di valvole. 
Collegamento elettrico per motore DC 
Esempio di schema di collegamento: 

 

Nel collegamento elettrico è importante considerare la sezione e la 
lunghezza  dei  cavi  di  alimentazione:  sezioni  troppo  piccole  e 

lunghezze  troppo  elevate  possono  causare  cadute  di  tensione  tali  da 
compromettere il buon funzionamento della UP. 
Prima della messa in funzione si consiglia di effettuare alcuni cicli di 
assestamento al teleruttore con cariche medio basse. 
 
Per  i  poli  del motore  e  del  teleruttore,  attenersi  alle  seguenti  coppie 

The above parameters, which are the result of experience and laboratory 
tests,  take  into  account  the  mounting  systems  and  fasteners  that  are 
essential  to  machineries  or  equipment  with  average  levels  of  vibration 
(transpallets in a workshop environment).  
 
INSTALLATION 

During  installation,  be  sure  that  important  assembling  operations 
are  carried  out  with  the  greatest  degree  of  cleanliness  in  a  clean, 

dust-free area. 

The  HPU must  be  installed  in  an ergonomic  position  that  provides 
easy access for inspection and maintenance. It is just as important 

to  install it  in  an  area  which  is  protected from  accidental  impact  and  kept 
away  from  accidental  physical  contact,  since  the  high  temperature  of  the 
unit during operation may cause burns. 
 

The HPU must be securely fastened to the machinery at its sturdiest 
points (such as the load-bearing frame, longitudinal members, etc), 
away from all sources of noise and vibration, and away from parts of 

machinery that may vibrate or transmit and/or amplify noise and vibration. 
HPU with a plastic tank must be installed in areas with limited temperature 
swings and away from direct exposure to sunlight. 

 

The  HPU must  be  installed  using  the two  ISO  M10  holes in  its  aluminum 
body. The HPU described above may be installed with a special foot that 
is  available  upon  request.  On  fixed  machineries  (horizontal  or  vertical 
position),  the  weight  limits  recommended  for  fastening  with  the  two  M10 
holes are: 

 

with B14 AC motor, size 112 

 

with 10 L tank 

 

with 12 L tank and the additional support of the feet on the tank. 

On moving machineries (the vertical position is preferable, mount the unit 
close to the center of gravity), the weight limits recommended for fastening 
with two M10 holes are: 

 

with all DC motors 

 

with 6 L tanks in sheet steel 

 

with 5 L tanks in PP 

 

with 4 L tanks in PE 

Tanks  with  a  higher  capacity  can  be  installed  on  HPU  for  special 
applications.    For  example,  the  tank  can  be  anchored  to  the  frame  of  a 
moving vehicle. 
General rules for correct installation 

Examine  the  hydraulic  diagram  and  the  electrical  diagram  (if 
available).    Our  technical/business  office  is  at  your  disposal  for 
further information/explanations. 
Avoid  removing  the  plastic  protection  plugs  until  you  connect  the 
hoses. 

Some electrically actuated valves have a screw-type manual safety 
device.  This  safety  must  be  deactivated  before  operating  the 

system.  

For HPU equipped with CETOP modular assemblies for connecting 
proportional  solenoid  valves,  use  DIN  3852  cylindrical  fittings  with 

UNI-ISO 228 threads as the connection ports. 
 

Remember  that  when  a  steel  fitting  with  a  dented  male  thread  is 
tightened,  it  will  remove  burrs  from  a  female  (aluminum)  seat.  
These burrs are the main cause of valve malfunctions. 

 
Connecting a DC motor 
Sample connection diagram: 

 

When wiring a motor, it is important to consider the cross-sectional 
area  and  length  of  the  power  cables.  Cables  with  overly  small 

cross-sections and overly long lengths may cause voltage drops that could 
prevent the HPU from operating properly. 
Before placing the HPU into service, we recommend cycling the start 
switch several times at low to medium loads to break in the switching 
system.  
Use  these  tightening  torque  values  on  the  motor  terminals  and  the 

Summary of Contents for DT Series

Page 1: ...ti accidentali o consequenziali dipendenti dall uso o dall inesperienza nell utilizzo del manuale o del prodotto DANA non sar responsabile per una cattiva od impropria installazione manutenzione ripar...

Page 2: ...a tenuta perfetta pertanto tale caratteristica deve essere considerata dall Utilizzatore in sede di progettazione della propria macchina o attrezzatura Le UP subiscono un collaudo funzionale e di veri...

Page 3: ...CE Motore AC Trifase e Monofase non applicabile Motore DC Campi avvolti conforme Motore DC Magneti permanenti non conforme compito dell Utilizzatore predisporre un filtro antidisturbo sulla linea di...

Page 4: ...le loro inferiori prestazioni nei confronti della temperatura Temperature ottimale di utilizzo dei serbatoi in lamiera e polietilene PE 10 C ambientale 70 C di esercizio Temperature limite di utilizzo...

Page 5: ...are la sezione e la lunghezza dei cavi di alimentazione sezioni troppo piccole e lunghezze troppo elevate possono causare cadute di tensione tali da compromettere il buon funzionamento della UP Prima...

Page 6: ...montato ingrassare le parti interne del gruppo leva e della valvola sulla quale il gruppo leva deve essere montato grasso per guarnizioni introdurre il gruppo leva fino al contatto fra camma e perno...

Page 7: ...rettamente il serbatoio vedere capitoli Smontaggio dei serbatoi e Sostituzione del filtro Prima di effettuare il cambio del fluido idraulico svuotare completamente tutto l impianto La frequenza del ca...

Page 8: ...la suddivisione tra le parti in acciaio e quelle in altri metalli o leghe per un corretto invio al riciclaggio per fusione L operazione di demolizione non presenta rischi particolari a condizione che...

Reviews: