110
Troubleshooting
F0026 (Fault Reason 74)
Error Description
Possible Causes
Possible Solutions
BMS has detected an abnormally
large charging current.
1) Defective charger.
1) Restart charging with a level 2
charger.
If the error disappears when the vehicle is connected
to a level 2 charger, the original charger maybe
defective.
HMI displays or logs
Fault code F0026 and
BMS fault reason 74
Unplug the EVSE from the
truck normally.
Restart the charge with
another level 2 EVSE.
Is the error still being
raised on further charge
cycles?
Yes
No
Contact Dana for further
investigation.
Complete
Remove power from EVSE.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...