Troubleshooting
F0028 - High Voltage System Fault
Error Description
Possible Causes
Possible Solutions
BMS derates the high voltage
power, limited to 50% due to an
ESS fault.
1) ESS fault.
1) Troubleshoot specific error.
This error is expected to be accompanied by error
F0026 which provides a BMS fault reason code
indicating the specific reason the limitation was
requested. The BMS will request the high voltage
power to be limited to 50% in response to fault
reason 4, 11, 14, 22, 23, 24, 32, 33, 34, or 40.
If error F0028 appears without one of the listed
F0026 BMS fault reasons, the technician should
contact Dana for further investigation.
HMI displays or logs
Fault code F0028
Is F0026 BMS 4/11/
14/22/23/24/32/33/34/40
also present?
Yes
No
Refer to the corresponding error
troubleshooting tree.
Contact Dana for further
investigation.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...