Troubleshooting
F0038 - High Voltage hazard
Error Description
Possible Causes
Possible Solutions
The VCU has detected a HV
system isolation fault during
charging.
1) ESS fault
1) Troubleshoot specific error
The VCU monitors voltage and current and raises an
error if the calculated isolation resistance falls below
a certain threshold.
The BMS independently monitors isolation
resistance and will raise error F0026 (BMS fault
reason 40, 41, 42, or 43) if there is a HV system
isolation fault condition detected. VCU and BMS
fault code may both appear for the same problem.
Warning:
Loss of HV system isolation can
pose an extreme hazard and may result in
high voltage being present in parts of the
vehicle that are not normally energized. Use
extreme caution and report all instances of
this error to Dana.
HMI displays or logs
Fault code F0038
Is F0026 BMS 43
also present?
Yes
No
Refer to error F0026 BMS 43
troubleshooting tree.
Contact Dana for further
investigation.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...