127
Troubleshooting
F0039 - Charging system limited
Error Description
Possible Causes
Possible Solutions
BMS has limited the charging rate
to 50% due to overheating in the
ESS.
1) ESS fault.
1) Troubleshoot specific error.
This error may be accompanied by one or more of
errors F0019, F0020, F0045, or F0119, indicating a
specific problem with the ESS cooling system. The
technician should troubleshoot the specific error.
HMI displays or logs
Fault code F0039
No
Yes
Is F0019, F0020 or
F0045 also present?
Refer to corresponding error
troubleshooting tree.
Is F0119 also
present?
Yes
Refer to error F0119
troubleshooting tree.
No
Stop the charge and wait for
the ESS to cooldown.
Is the error still being
raised on further charge
cycles?
Start the charge again
Yes
Contact Dana for further
investigation.
No
Complete
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...