Troubleshooting
HMI displays or logs
Fault code F0146
Disconnect connector C724 from chiller.
Refer to connector investigation
With a multimeter, check for continuity between the
following points:
- Continuity : Resistance is less than or equal to 2ohms.
Cradle C724S
Tank C724S
Connector pin
Connector pin
Pin 3
Pin 4
Is there any evidence of
a continuity loss ?
No
Yes
Defective harness.
Replace harness.
Contact Dana for further
investigation.
Is F0019 or F0020
also present?
No
Yes
Refer to corresponding error
troubleshooting tree.
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.
Is there any
problem with the
connector
integrity?
Yes
No
Defective connector.
Replace harness.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...