164
Troubleshooting
F0005, F0006, F0007 (Charge end reason 1)
Error Description
Possible Causes
Possible Solutions
VCU has terminated the charging
process in response to a request
from the BMS.
1) ESS fault.
2) Incompatible or defective
EVSE.
1) Troubleshoot specific error.
2) Restart charge with compatible
EVSE.
This error is expected to be accompanied by error
F0042. If this is the case, the technician should
troubleshoot error F0042.
If error F0042 has not been raised, it may be
possible to resolve the error by restarting the charge
using a compatible EVSE.
Note:
When requested to connect the
vehicle to an EVSE, either a level 2 or level
3 EVSE can be used.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...