194
Troubleshooting
F0005, F0006, F0007 (Charge end reason 16)
Error Description
Possible Causes
Possible Solutions
BMS has reported that charging is
completed.
1) Charging completed
successfully (no error).
2) ESS fault.
3) Incompatible or defective
EVSE.
1) No action needed; this is the
intended vehicle function.
2) Troubleshoot specific error.
3) Restart charge with compatible
EVSE.
This message is not displayed to the driver but may
still appear in the HMI fault log. If charge controller
Charge end reason 16 appears without any other
errors and the SOC is at 100% then the charging
system is operating correctly, and no troubleshooting
is needed.
It may be possible to resolve the error by restarting
the charge with a compatible EVSE.
If error F0153, F0154, or F0155 is raised, the SOC
measurement may not be accurate. The technician
should troubleshoot F0153, F0154, or F0155 first.
Note:
When requested to connect the
vehicle to an EVSE, either a level 2 or level
3 EVSE can be used.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...