226
Troubleshooting
F0005, F0006, F0007 (Charge end reason 30)
Error Description
Possible Causes
Possible Solutions
Charge controller status message
indicating a specific state of the
charge inlet.
1) Charger operating normally
(no error).
2) EVSE error.
1) No action needed; this is the
intended vehicle function.
2) Restart charge session.
This message is not displayed to the driver but may
still appear in the HMI fault log. If charge controller
fault reason 30 appears without any other errors and
the SOC is at 100% or other operator-defined
maximum, then the charging system is operating
correctly, and no troubleshooting is needed.
Otherwise, it may be possible to resolve the error by
restarting the charge with a compatible EVSE.
Note:
When requested to connect the
vehicle to an EVSE, either a level 2 or level
3 EVSE can be used.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...