256
Troubleshooting
HMI displays or logs
Fault code F0088 and
OBC fault reason 0x400C/ 0x400B,
0x410A/0x410C/0x400A/0x410B
Contact Dana for further
investigation.
Were you able to find a
problem in the CAN B
network?
Yes
No
Refer to CAN investigation subtree
Repair according to the
actions prescribed in the
subtree.
Is the error code still
displayed?
Yes
No
Complete
Is the error still occurring
on further key ON or
charge cycles?
No
Yes
Complete
Update the OBC software version
following the STT01 tree provided in
the TM4 troubleshooting guide.