259
Troubleshooting
HMI displays or logs
Fault code F0088 and
OBC HVIL error
Does the HMI also display
F0061, F0062 or F0063?
No
Yes
Refer to the corresponding error
troubleshooting tree.
Disconnect connector C731 and C727
from OBC.
Refer to connector investigation
With a multimeter, check for continuity between the
following points:
- Continuity : Resistance is less than or equal to 2ohms.
OBC C731P
Connector
Pin HVIL_A
Pin HVIL_B
OBC C731P
Connector
OBC C727S
Connector
Pin HVIL1
Pin HVIL2
OBC C727S
Connector
Is there any evidence of
a continuity loss?
No
Yes
Defective harness.
Replace harness.
Defective OBC.
Replace OBC.
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.
Is there any
problem with the
connector
integrity?
Yes
Defective connector.
Replace harness.
No
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...