Troubleshooting
F0097, F0098 (Fault Reason 4)
Error Description
Possible Causes
Possible Solutions
Traction inverter has limited
regenerative braking (F0097) or
traction (F0098) due to
overheating in the motor or traction
inverter.
1) Adverse driving conditions.
2) Cooling fault.
3) Cooling system problem.
4) Traction inverter internal
failure.
1) Park vehicle outdoors out of
the sun and allow it to cool
down for 2 hours.
2) Troubleshoot specific error.
3) Resolve cooling system
problem.
4) Replace traction inverter.
This error can occur if the ambient temperature is
very high or if driving conditions are very taxing
(maximum speed, maximum torque, steep uphill or
downhill). In these cases, the problem can be
resolved by allowing the vehicle to cool down.
Propulsion System faults may also be
investigated and resolved using the ODIN
tool and the TM4 SUMO Powertrain
Troubleshooting Guide.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...