285
Troubleshooting
Flash the traction inverter to the latest
software and calibration following the
instructions in the TM4 installation
manual.
Is the problem
persisting on further
drive cycles in similar
conditions?
No
Yes
Complete
HMI displays or logs
Fault code F0097 and Fault reason 6
Fault code F0098 and Fault reason 6
Was this error raised on a
steep slope or at maximum
speed?
Yes
No
Complete
Contact Dana for further
investigation.