289
Troubleshooting
Disconnect connector C701 and
C702 from HV junction box.
Disconnect connector C718,
C719, C716 and C717 from S-
Box.
Is there any evidence of
a continuity loss?
Refer to the connector investigation
No
Yes
Defective harness.
Replace harness.
Contact Dana for further
investigation.
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.
A
With a multimeter, check for continuity between the
following points:
- Continuity : Resistance is less than or equal to 2ohms.
HV JB C702P S-Box C718P
Connector pin
Connector pin
Pin 1
Pin 1
HV JB C702P S-Box C719P
Connector pin
Connector pin
Pin 1
Pin 1
HV JB C701P S-Box C717P
Connector pin
Connector pin
Pin 1
Pin 1
HV JB C701P S-Box C716P
Connector pin
Connector pin
Pin 1
Pin 1
Is there any
problem with the
connector
integrity?
Yes
No
Defective connector.
Replace harness.
A
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...