Troubleshooting
F0019 (Fault Reason 32)
Error Description
Possible Causes
Possible Solutions
Battery TMS has detected a
precharge failure.
1) ESS fault.
2) Battery TMS internal failure.
1) Troubleshoot specific error.
2) Replace Battery TMS.
The precharge circuit manages the voltage ramp-up
of the HV system upon startup of the vehicle.
Precharge ends when the voltage of the HV
distribution system reaches 95% of the ESS voltage.
The vehicle is then enabled to start. If the HV
distribution system fails to reach the required
threshold within 5 seconds, the VCU will flag
precharge as failed and the vehicle startup will be
aborted.
Precharge errors may also to be raised by the BMS
(F0026) and VCU (F0017) if Battery TMS fault
reason 32 appears.
Does the HMI also
display F0017?
No
Yes
Refer to F0017 troubleshooting
tree.
Does the HMI also
display F0026?
Yes
Refer to the corresponding
troubleshooting tree.
No
Defective Battery TMS.
Replace Battery TMS.
HMI displays or logs
Fault code F0019 and
TMS fault reason 32
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...