34
Troubleshooting
HMI displays or logs
Fault code F0019 and
TMS fault reason 34
Contact Dana for further
investigation.
Is any other system on the
HV DC bus raising an
overvoltage error?
No
Yes
Does the HMI also display
F0026?
Yes
Refer to the corresponding
error troubleshooting tree.
No
Disconnect connector RT063
from Battery TMS.
Disconnect connector RT064
from HV junction box.
Check the connectors for
corrosion, scorching, or physical
integrity loss.
With a multimeter, check for continuity between the
following points:
- Continuity : Resistance is less than or equal to 2ohms.
RT063
RT064
Connector pin
Connector pin
RT063
RT064
Is there any evidence of a
continuity loss in the
harness?
No
Yes
Defective harness.
Replace harness.
Contact Dana for further
investigation.
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...