Troubleshooting
F0002 (Fault Reason 0x4ff8e4)
Error Description
Possible Causes
Possible Solutions
iAPU has reported that its supply
voltage is out of range.
1) DCDC or LV distribution fault.
2) Blown 24V fuse F2.
3) Loss of continuity due to
defective LV connector or
harness.
4) iAPU internal failure.
1) Troubleshoot specific error.
2) Replace 24V fuse F2.
3) Replace LV connector or
harness per Service Manual.
4) Contact Dana.
Connector C40
Connector C203
Connector C367P (pin)