446
Troubleshooting
F0008 (Fault Reason 16)
Error Description
Possible Causes
Possible Solutions
VCU has detected a mismatch
between the DCDC output voltage
and EHPS motor controller input
voltage.
1) Compatibility problem with
aftermarket accessory.
2) At least one low voltage
battery defective, not to spec,
or wired incorrectly.
3) Defective LV harness between
DCDC and EHPS motor
controller.
1) Disconnect incompatible
accessory.
2) Replace low voltage battery or
repair battery wiring.
3) Replace LV connector or
harness per Service Manual.