451
Troubleshooting
F0009 - 12V/24V Charging System Fault
Error Description
Possible Causes
Possible Solutions
The DCDC has detected that its
internal temperature is too high.
1) Cooling system problem.
1) Resolve cooling system
problem.
HMI displays or logs
Fault code F0009
Does the HMI also
display error F0059 or
F0060?
No
Yes
Refer to the corresponding
troubleshooting tree.
Does the HMI also
display error F0008
(DCDC fault reason
11)?
No
Yes
Contact Dana for further
investigation.
Is the error still
raised?
No
Yes
Disconnect the coolant hoses
from the DCDC and check that
the flow path is not obstructed.
Was any root cause
identified in the
cooling system?
Yes
No
Complete
Contact Dana for further
investigation.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...