452
Troubleshooting
F0144 - Potential High Voltage Hazard! DCDC HVIL Fault
Error Description
Possible Causes
Possible Solutions
DCDC has detected a discontinuity
in the high voltage interlock loop
(HVIL).
1) HV connector unplugged.
2) Defective HV connector or
harness.
1) Plug in HV connector.
2) Replace HV harness.
The purpose of the HVIL is to provide a warning if
any HV connector is unplugged without the HV
distribution being safely ended. The DCDC monitors
continuity between the HVIL pins on its HV
connector (C730). If this connector is unplugged
unsafely, the HVIL will be broken and the DCDC will
send an error message via CAN.
If error F0061, F0062, or F0063 also appears, it is
possible that connector C712 on the HV junction box
is disconnected or faulty.
Connector C730
Connector C712
3
4
4
3
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...