Troubleshooting
F0010, F0011, F0012, F0013, or F0014 EHPS service code 5202
Error Description
Possible Causes
Possible Solutions
The EHPS motor controller detects
a problem resulting in possible
failure of the power steering
system.
1) Temperature on power stage
has reached warning
temperature parameter.
1) Dirt accumulation on heat sink
or fan.
2) System overload.
3) Ambient temperature exceeds
50°C.
Inspect the power steering oil
circuit for leaks and clogs.
Are there any leaks or
clogs in the power
steering oil circuit?
No
Repair the circuit
accordingly.
Yes
Inspect the pump for possible
defects.
When troubleshooting EHPS service code
5202, the technician is instructed to check
the hydraulic system for root causes.
Continued on next page
HMI displays or logs
Fault code F0010/F0011/F0012/F0013/F0014
and EHPS service code 5202
Refer to the Dana TM4
EHPS Motor Controller MI06
Troubleshooting Guide for code 5202.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...